Updated Sep-2023 100% Cover Real 5V0-22.21 Exam Questions Make Sure You 100% Pass
5V0-22.21 dumps Accurate Questions and Answers with Free and Fast Updates
NEW QUESTION # 63
A host in a vSAN cluster has the following VMware Compatibility Guide approved disks:
* 3 Solid State Drive (SSD) used for cache
* 12 magnetic Hard Disk Drives (HDD) used for capacity
Which two options are valid disk group configurations? (Choose two.)
- A. 3 Disk Groups with 1 SSD and 4 HDD each
- B. 2 Disk Groups with 1 SSD and 6 HDD each
- C. 4 Disk Groups with 3 HDD each
- D. 1 Disk Group with 3 SSD and 12 HDD
- E. 1 Disk Group with 2 SSD and 6 HDD
Answer: A,B
Explanation:
A disk group requires the following: * One flash device for caching * One to seven capacity devices for storage A host can include a maximum of five disk groups.
NEW QUESTION # 64
A single disk in a vSAN disk group suffers from an unrecoverable hardware failure. This causes vSAN to set the health status for all disks in the group to Permanent disk loss, indicating disk failure. All other disks, however, have not suffered from a hardware failure.
Why would vSAN mark all disks in this manner?
- A. Deduplication and compression are enabled.
- B. The key management server is offline.
- C. The vSAN disk management service has failed.
- D. The affected vSAN node is offline.
Answer: D
Explanation:
If a single disk in a vSAN disk group suffers from an unrecoverable hardware failure, vSAN will mark all disks in the group with a Permanent disk loss status. This is because vSAN uses a technique called "failure domains" to ensure data availability and protect against data loss. A failure domain is a group of disks that are considered a single point of failure. If a disk in a failure domain fails, all other disks in that failure domain are also considered failed. This is to protect against further data loss in the event of a second failure in the same failure domain.
Reference:
VMware vSAN 6.7 Documentation > vSAN > vSAN Operations > Managing vSAN > Understanding and Managing Failure Domains in vSAN VMware vSAN 6.7 Documentation > vSAN > vSAN Operations > Managing vSAN > Understanding Health and Performance > Understanding Disk Group Health
NEW QUESTION # 65
Which two actions are recommended when adding a host to a vSAN cluster? (Choose two.)
- A. Disable vSphere Cluster Services (vCLS).
- B. Create uniformly-configured hosts.
- C. Disable vSAN performance service.
- D. Disable vSphere High Availability (HA).
- E. Reference the VMware Compatibility Guide.
Answer: B,E
NEW QUESTION # 66
A new host with local storage devices has been added to a vSAN cluster. Now, the administrator would like to increase the capacity of the vSAN datastore.
What must be done to the new host to accomplish this goal?
- A. Configure a RAID set on the storage controller.
- B. Delete all existing partitions.
- C. Perform a storage device rescan.
- D. Create one or more disk groups.
Answer: B
NEW QUESTION # 67
A vSAN administrator is using the vSAN ReadyNode Sizer to build a new environment. While entering the cluster configurations, a fellow colleagues inquire about the Operations Reserve option.
What is the purpose of using this option?
- A. Configures space for external operations
- B. Provides space for internal operations
- C. Reserves space for tolerating failures
- D. Allocates space forvSAN upgrades
Answer: B
NEW QUESTION # 68
When attempting to add a directly attached disk device to a host disk group, the intended disk does not show among the available devices in disk management.
Which action should be taken?
- A. Delete all device partitions
- B. Create a VMFS partition
- C. Format the existing partition
- D. Create a 1GB metadata partition
Answer: A
NEW QUESTION # 69
A vSAN administrator is tasked to perform an upgrade of a vSAN cluster from 7.0 to 7.0 U2, including firmware and drivers for its hardware. The vSAN administrator already created an image using vSphere Lifecycle Manager (vLCM).
Prior to selecting Start Remediation, which step should be taken to upgrade the complete vSAN cluster as a single task?
- A. Select Remediate All through vLCM to upgrade all hosts in the cluster.
- B. Manually remediate one host at a time in the vSAN cluster.
- C. Place all hosts in the vSAN cluster into Maintenance Mode.
- D. Stage the upgrade of the vSAN cluster through vLCM.
Answer: B
NEW QUESTION # 70
A newly deployed vSAN cluster runs vSAN 7.0, and the vSAN cluster needs an integration with a third-party software solution. The software solution provides full app-level redundancy, and it runs on the vSAN Data Persistence platform.
The administrator configures vSAN Direct Configuration to integrate the third-party storage with vSAN and now needs to configure a storage policy to make sure the vSAN Direct storage is used by the vSAN Data Persistence platform third-party software solution.
Which type of storage policy configuration should the administrator use?
- A. AvSAN storage policy with one failure to tolerate (N 1=1)
- B. A storage policy with capability-based rules for third-party storage
- C. A vSAN shared nothing policy with no data redundancy (FTT=0)
- D. A storage policy with tag or capability-based rules for vSAN Direct
Answer: D
NEW QUESTION # 71
An existing vSAN cluster has this specification:
Four ESXi hosts with all flash configuration
Each with two disk groups
Each disk group with one cache device and four capacity devices
There are five more device slots available
The CTO would like to provision new applications, and these will need more capacity and performance.
Which two methods may be used by the vSAN administrator to meet this goal? (Choose two.)
- A. Replacing all capacity devices by a larger device
- B. Replacing all cache devices by a larger device
- C. Adding an ESXi host with identical device configuration
- D. Adding faster cache devices
- E. Adding one more disk group per host with the same configuration
Answer: C,E
NEW QUESTION # 72
An enterprise company is carrying out a planned yearly power test on specific platforms, and the infrastructure administrator has been asked to power down a vSAN 7.0 U1 cluster containing production virtual machines. The management workloads, such as the vCenter Server, are running on a different platform.
Which action should the vSAN administrator take to ensure it is safe to complete this task?
- A. Review Data Migration Pre-Check results from the vSphere client
- B. Review the vSAN proactive tests results from the vSphere client
- C. Enter Maintenance Mode with Full data migration
- D. Enter Maintenance Mode with ensure accessibility option
Answer: D
Explanation:
The correct action to take to ensure it is safe to power down a vSAN 7.0 U1 cluster containing production virtual machines is to enter Maintenance Mode with the Ensure Accessibility option. This option will migrate the data from the disk groups in the vSAN cluster to other disk groups in the same cluster, and will allow the administrator to power down the cluster without any data loss.
NEW QUESTION # 73
An administrator is tasked with upgrading a network isolated vSAN Cluster to the latest version available to take advantage of the new features and performance improvements.
Which two actions should the administrator take first? (Choose two.)
- A. Login on MyVMware, and download the vSphere and vSAN software bundles.
- B. Disable the vSphere DRS and vSphere HA in order to avoid VMs and data from moving among the nodes during the vSAN upgrade process.
- C. Verify if there is enough cache devices and cache space on the hosts before proceeding with the software updates.
- D. Put the host in maintenance mode with "Ensure Accessibility".
- E. Verify the supportability of the software, hardware, drivers, firmware, and storage I/O controllers on the VMware Compatibility Guide.
Answer: A,E
Explanation:
The correct answers are D. Login on MyVMware, and download the vSphere and vSAN software bundles and E. Verify the supportability of the software, hardware, drivers, firmware, and storage I/O controllers on the VMware Compatibility Guide. Before upgrading the vSAN cluster, the administrator should first login to MyVMware and download the vSphere and vSAN software bundles, and then verify the supportability of the software, hardware, drivers, firmware, and storage I/O controllers on the VMware Compatibility Guide. Once the compatibility has been verified, the administrator can proceed with disabling vSphere DRS and vSphere HA in order to avoid VMs and data from moving among the nodes during the vSAN upgrade process, and then put the host in maintenance mode with "Ensure Accessibility".
https://docs.vmware.com/en/VMware-vSphere/7.0/rn/vsphere-vcenter-server-701-release-notes.html VMware vCenter Server 7.0 Update 1 Release Notes
https://docs.vmware.com/en/VMware-vSphere/7.0/rn/vsphere-vcenter-server-701-release-notes.html
https://www.vmware.com/content/dam/digitalmarketing/vmware/en/pdf/products/branding/vmware-trademark-guidelines.pdf VMWARE TRADEMARK GUIDE
https://www.vmware.com/content/dam/digitalmarketing/vmware/en/pdf/products/branding/vmware-trademark-guidelines.pdf
https://docs.vmware.com/en/VMware-vSphere/7.0/vsan-703-monitoring-troubleshooting-guide.pdf vSAN Monitoring and Troubleshooting - VMware vSphere 7.0
https://docs.vmware.com/en/VMware-vSphere/7.0/vsan-703-monitoring-troubleshooting-guide.pdf
NEW QUESTION # 74
A 100GB virtual disk object has this storage policy assigned to it:
Site disaster tolerance: None - standard cluster
Failures to Tolerate: 1 failure - RAID-1 (Mirroring)
Number of disk stripes per object: 3
What is the maximum amount of raw vSAN storage capacity consumed by this virtual disk?
- A. 200GB
- B. 100GB
- C. 300GB
- D. 600GB
Answer: B
NEW QUESTION # 75
A new vSAN Cluster with four hosts has to be designed for a single site architecture.
Which design decision is correct?
- A. Only hardware listed on the VMware Compatibility Guide will be deployed.
- B. Configure the storage controllers to use RAID.
- C. Use block-based storage for the newvSAN cluster.
- D. All the data must remain accessible even with two host failures.
Answer: B
NEW QUESTION # 76
A 100GB virtual disk object has this storage policy assigned to it:
Site disaster tolerance: None - standard cluster
Failures to Tolerate: 1 failure - RAID-1 (Mirroring)
Number of disk stripes per object: 3
What is the maximum amount of raw vSAN storage capacity consumed by this virtual disk?
- A. 100GB
- B. 200GB
- C. 300GB
- D. 600GB
Answer: B
NEW QUESTION # 77
A vSAN administrator is receiving complaints that applications are not performing as expected. The vSAN administrator opens the vSAN cluster performance charts to try to identify the issue, but the vSAN cluster performance charts are not available.
Which option should vSAN administrator enable to make these charts available?
- A. vSAN Performance Diagnostics
- B. vSAN Performance Service
- C. vSAN Troubleshooting Diagnostics
- D. vSAN Troubleshooting Service
Answer: B
NEW QUESTION # 78
What are two characteristics of the vSAN Data-At-Rest Encryption (DARE)? (Choose two.)
- A. It continues to operate unaffected during downtime on vCenter Server.
- B. It is Software Defined and works independently of the Cache or Capacity drives installed on the Nodes.
- C. It needs to be enabled together with the vSAN Data-In-Transit encryption.
- D. It is not supported on Stretched Cluster environments.
- E. It requires Self-Encrypting Drives in order to work.
Answer: A,B
Explanation:
Two characteristics of the vSAN Data-At-Rest Encryption (DARE) are that it is Software Defined and works independently of the Cache or Capacity drives installed on the Nodes, and it continues to operate unaffected during downtime on vCenter Server. According to VMware's Official Guide, "vSAN Data-At-Rest Encryption (DARE) is a software-defined solution that works independently of the Cache or Capacity drives installed on the Nodes". Additionally, "DARE continues to operate unaffected during downtime on vCenter Server". Thus, these two characteristics make DARE an ideal encryption solution for vSAN.
NEW QUESTION # 79
Which option, if any, is the default option to enable Maintenance Mode on a vSAN host?
- A. Ensure accessibility.
- B. No data migration.
- C. Full data migration.
- D. There is no default option. The administrator must select an option.
Answer: D
NEW QUESTION # 80
A vSAN administrator has deployed a new All-Flash vSAN cluster and would like to perform a health test on it to verify that the network performance is meeting the network throughput requirements.
Which tool should be used for this purpose?
- A. vSAN Cluster Performance
- B. lOlnsight
- C. vSAN Skyline
- D. vSAN Proactive Test
Answer: D
Explanation:
According to the VMware vSAN documentation [1], the vSAN Proactive Test is a built-in feature of vSAN that can be used to test the health of a vSAN cluster and verify that the network performance meets the throughput requirements. This tool can be accessed through the vSAN Health Service. [1] https://docs.vmware.com/en/VMware-vSphere/7.0/vsphere-esxi-vcenter-server-70-vsan-health-service-guide.pdf
NEW QUESTION # 81
A vSAN Administrator has a cluster of six vSAN nodes. The vSAN datastore was 55% utilized, and due to a power outage, one node was lost. The vSAN administrator needs to resolve the storage policy compliance for the virtual machines on RAID-5.
Which action, if any, needs to be taken to meet this goal?
- A. The one failed node must be restored.
- B. Trigger vSAN object repair from ESXCLI.
- C. No action is needed since vSAN automatically rebuilds the objects.
- D. Change the RAID-5 FTT from 2 to 1.
Answer: D
Explanation:
When a node is lost in a vSAN cluster, the vSAN will automatically begin to rebuild objects in order to meet the storage policy compliance. However, if the storage policy includes RAID-5 with a "Failures to Tolerate" (FTT) value of 2, it won't be possible to rebuild the objects and meet the storage policy compliance with only 5 nodes. In this case, the vSAN administrator needs to change the RAID-5 FTT from 2 to 1, this will allow the vSAN to rebuild the objects and meet the storage policy compliance with only 5 nodes. With RAID-5, the FTT value of 1 is the minimum value supported by vSAN.
This is explained in VMware vSAN documentation in the section "RAID-5 and RAID-6 Erasure Coding" Reference: https://docs.vmware.com/en/VMware-vSphere/7.0/vsphere-vsan-70-config-guide/GUID-1A5F48D5-F8C9-4C7E-9D9B-F9D4B4E4A4F4.html Changing the RAID-5 FTT from 2 to 1 will ensure that the virtual machines on the vSAN datastore are in compliance with the storage policy. This is because, with a RAID-5 FTT of 2, the cluster needs at least 6 nodes to meet the redundancy requirements. With a single node lost, the cluster cannot meet this requirement and so the virtual machines on the datastore will be out of compliance. By changing the FTT from 2 to 1, the cluster will be able to meet the redundancy requirements with only the remaining 5 nodes, ensuring compliance with the storage policy. Reference: https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.troubleshooting.doc/GUID-F7A0FECC-E95E-4A89-B3B3-9699D9F7D87D.html
NEW QUESTION # 82
A customer is running a number of compute-intensive application workloads on their existing 4-node vSAN cluster that has resulted in resource contention. To provide additional compute resources, the vSAN administrator has decided to deploy a new 4-node vSAN compute-only cluster so that a HCI Mesh can be configured.
Which three points would the vSAN administrator need to consider before using this configuration? (Choose three.)
- A. A storage policy of Erasure Coding with hi 1=1 would be supported.
- B. The storage policy must be based on the number of hosts within the server cluster.
- C. A storage policy of Erasure Coding with FTT=2 would be supported.
- D. The storage policy is based on the total number of hosts across both client and server clusters.
- E. The storage policy must be based on the number of hosts within the client cluster.
- F. A storage policy of Mirroring with FIT 1 would be supported.
Answer: A,B,F
NEW QUESTION # 83
A vSAN administrator has been tasked with troubleshooting an application in a Hybrid vSAN environment. The application is I/O intensive, and the magnetic capacity devices may be playing a role in slow performance, so the administrator decides to take action to help resolve the problem.
Which action should the administrator take?
- A. Add more magnetic capacity devices in the affected host.
- B. Change the Default Storage Policy to have stripe width of 13.
- C. Modify the stripe width for the application on the advanced settings for the VM.
- D. Increase the stripe width based on the number of capacity devices within the disk group.
Answer: D
NEW QUESTION # 84
A vSAN administrator was examining the status of Virtual Objects and found inaccessible objects that are occupying significant storage capacity.
Refer to the exhibit:
Which action is needed to restore the storage capacity?
- A. Trigger a manual resync, and allow vSAN to heal the object.
- B. Evacuate data on affected node by using the Full Data Migration mode.
- C. Restart the host, and obsolete objects will be removed on their own.
- D. Identity and remove the obsolete object.
Answer: A
NEW QUESTION # 85
Which solution can automate the deployment of a vSAN cluster as part of a full Software-Defined Datacenter?
- A. VMware Cloud Foundation
- B. vRealize Suite Lifecycle Manager
- C. VMware Cloud Director
- D. vSphere Replication
Answer: A
NEW QUESTION # 86
Which state is NOT a compliance status of a VM Storage Policy?
- A. Noncompliant
- B. Stale
- C. Not Applicable
- D. Compliant
Answer: B
NEW QUESTION # 87
A vSAN administrator of a network isolated vSAN environment wants to upgrade the environment from the vSAN 7.0 to the vSAN 7.0 U1 using vLCM.
Which option, if any, should be used as a depot in this case?
- A. Configure the vSphere Lifecycle Manager to download the updates from the VMware Depot using HTTPS.
- B. Configure the vSphere Lifecycle Manager to download updates from a local UMDS-shared repository.
- C. Configure the vSphere Lifecycle Manager to download the updates from an Online Depot.
- D. It is not possible to use the vSphere Lifecycle Manager on a network isolated environment.
Answer: A
NEW QUESTION # 88
......
Preparing for the VMware vSAN Specialist Exam requires a thorough understanding of vSAN technology and its features. Candidates are advised to have hands-on experience with vSAN environments, as well as to have completed the recommended training courses. VMware offers several courses and resources to help candidates prepare for the exam, including VMware vSAN: Deploy and Manage and VMware vSAN: Troubleshooting. Candidates can also find additional study materials, such as practice exams and study guides, to help them prepare for the exam.
Real 5V0-22.21 Quesions Pass Certification Exams Easily: https://passguide.braindumpsit.com/5V0-22.21-latest-dumps.html